Power Water Usage
Basic Max. Fuse Min. BTU’s Shipping Consumption Gallons/100 lbs.
Model Condenser Electrical Size or HACR Comp. Circuit Circuit per Weight KWH/100 lbs. Potable Condenser
Number Unit Volts/Hz/Phase Circuit Breaker HP Wires Ampacity hour lbs./kg. 90°F/70° F 90°F/70° F 90°F/70° F
CME2006RS-32D Remote 208-230/60/1 40 4.0 2 30 40,000 370/168 5.8 17.5 –
CME2006RS-3D Remote 208-230/60/3 30 4.0 3 20 40,000 370/168 5.8 17.5 –
CM3
Ice Machine Specifications
All units with Stainless Steel finish.
Refrigerant: R-404A.
OPTIONS:
Stacking Kit: KSCME6-LG
ERC611-32A (1) CME2006R Air Galvanized 208-230/60/1 2 1.25 15
Model
Number For Use With Cond. Unit
Finish
Basic
Electrical
Volts/Hz/
Phase No. of Wires
Min. Circuit
Ampacity
Max Fuse
Size or
HACR Circuit
Braker
REMOTE CONDENSER—Comes with adjustable legs
Dimensions: W x D x H: 29.50˝ x 38.00˝ x 38.50˝
All models: Dimensions: W x D x H Unit: 48˝ x 24˝ x 28˝ Shipping Carton: 51˝ x 27˝ x 31˝
IMPORTANT OPERATING REQUIREMENTS:
Minimum Maximum
Air Temperatures 50
0
F (10
0
C) 100
0
F (37.7
0
C)
Water Temperatures 40
0
F (4.4
0
C) 100
0
F (37.7
0
C)
Remote Cond. Temps -20
0
F (-28.9
0
C) 120
0
F (48.9
0
C)
Water Pressures 20 PSIG 120 PSIG
Electrical Voltage -5% +10%
PRE-CHARGED REFRIGERANT TUBE KITS: 25-Foot, LRTE25-25 • 40-Foot, LRTE40-40 • 75-Foot, LRTE75-75, Refrigerant: R-404A.
Consult Your Local SCOTSMAN Representative At:
Machine requires voltage indicated on rating name plate. Failures caused by improper voltage are not considered
factory defects. Extended periods of operation at temperatures exceeding limitations constitutes misuse under the
terms of Scotsman Manufacturer’s Limited Warranty, resulting in a loss of warranty coverage. Specifications and
design are subject to change without notice.
Scotsman’s ice machines are not designed for outdoor installations. Scotsman remote condensers are
designed for outdoor installations.
.562 DIA.
3/89 MALE CPLG.
1/29 MALE CPLG.
88 DIA. ELECTRICAL
Komentáře k této Příručce