INTRODUCTION
To the owner or user: This service manual is
intended to provide you and the maintenance or
service technician with the information needed to
install, start up, clean, maintain and service this
ice system.
Table of Contents
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
For the Installer
Location & Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
For the Electrician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
For the Plumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Final Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Freeze Cycle Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Harvest Cycle Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Component Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Service Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Parts Lists and Wiring Diagrams are located
in the center of this manual, printed on
yellow paper.
CMS1202R
September 1993
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 26 27

Shrnutí obsahu

Strany 1 - CMS1202R

INTRODUCTIONTo the owner or user: This service manual isintended to provide you and the maintenance orservice technician with the information needed t

Strany 2

INITIAL START UPBefore Start Up: 1. Check that the ICE-OFF-WASH rocker switchand the Compressor ON-OFF switch are in theOFF position. 2. Switch on the

Strany 3

INITIAL START UP9. Check operation of the freezing cycle: Ice willbegin to from from the top of the evaporatorsdown. After the first cycle, freezing t

Strany 4

FREEZING CYCLE OPERATIONWater from the sump assembly is pumped to thewater distributor system at the top of eachevaporator plate. From the water distr

Strany 5

HARVEST CYCLE - HOT GAS BYPASS When the timer switches the icemaker into theharvest cycle, high pressure, high temperature gasrefrigerant being discha

Strany 6

COMPONENT DESCRIPTIONCube Size ControlThis reverse acting thermostat controls the lengthof the freezing cycle. It is sensing the temperatureof the suc

Strany 7

COMPONENT DESCRIPTIONBin Level ControlThis electronic control uses sound waves tomeasure the distance between the bottom of theice machine and the top

Strany 8

COMPONENT DESCRIPTIONWater Inlet Solenoid Valve The water inlet solenoid valve fills the sumpassembly with water and excess water overflowsout the sta

Strany 9

CLEANING//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Strany 10

CLEANINGRemote Condenser1. Shut off the ice machine.2. Remove dirt and debris that might be under thecondenser.3. Brush off the bottom of the condense

Strany 11

SYSTEM SPECIFICATIONSThe following numbers can be used as a guideline. There will be some variation from unit to unit.Typical Cycle Time••17 minutes @

Strany 12

Model Number Dimensions(without bin)W" x D" x H"BasicElectricalRefrigerant TypeMinimumCircuitAmpacity*MaximumFuseSizeRefrigerant Charge

Strany 13

ADJUSTMENTSAdjustment Of The Timer & Switch AssemblyOne complete revolution of the cam on the timertakes eight minutes. The normal setting is thre

Strany 14

SERVICE DIAGNOSIS: WaterSYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice is made Inlet water valve will not open or isdirtyClean inlet screen, check coil,rep

Strany 15

SERVICE DIAGNOSIS: Electrical and/or AdjustmentsSYMPTOM POSSIBLE CAUSE PROBABLE FIXMachine does not operate No power Reconnect powerHigh pressure cont

Strany 16

SERVICE DIAGNOSIS: Refrigeration and/or MechanicalSYMPTOM POSSIBLE CAUSE PROBABLE FIXPoor harvest Hot gas valve does not open Check for power to the c

Strany 17

CONDITION DETERMINE CAUSE PROBABLE CORRECTIONIce Machine does not run, it haspower to it, the high pressure controlis closed, the on/off switch is set

Strany 18

REMOVAL AND REPLACEMENTWater Distributor Tubes And Manifold Tubes To remove the water distributor tube and manifoldtube: 1. Remove the front panel. 2.

Strany 19

Water Pump1. Remove front panel.2. Unplug water pump electrical connection.3. Drain water reservoir.4. Use corbin clamp pliers to loosen and slidecorb

Strany 20

Thermostatic Expansion Valve1. Before replaceing this valve, be certain that thevalve is the cause of the problem, and cannot beadjusted.2. Remove the

Strany 21

FOR THE INSTALLER: Location & AssemblyLocation:After uncrating and inspection, the unit is ready forinstallation. It is important that the machine

Strany 22

FOR THE INSTALLER: Location & AssemblyStacking InstructionsWhen stacking two units, remove the top paneland the evaporator cover from the lower ic

Strany 23

FOR THE INSTALLER: Remote CondenserLocate the condenser as near as possible tothe interior location of the ice maker. Location of the condenser is lim

Strany 24

FOR THE INSTALLER: Coupling Instructions////////////////////////////////CAUTION/////////////////////////////////The couplings on the sets of precharge

Strany 25

FOR THE ELECTRICIAN SEE NAMEPLATE for current requirements todetermine wire size to be used for electricalhookup. When the cuber and the remotecondens

Strany 26

FOR THE PLUMBERThe recommended water supply line is a 3/8-inchO.D. copper tubing with a minimum operatingpressure of 20 PSIG and a maximum of 80 PSIG.

Strany 27

FINAL CHECK LIST1. Is the cabinet in a room where ambienttemperatures are within the minimum andmaximum temperatures specified?2. Is there clearance a