Scotsman FME504 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Stroj na výrobu ledu Scotsman FME504. Scotsman FME504 User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation and
User's Manual for
Flake and Nugget Ice Machine
Models FME504, FME804, NME454,
NME654
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Flake and Nugget Ice Machine

Installation andUser's Manual forFlake and Nugget Ice MachineModels FME504, FME804, NME454,NME654

Strany 2

CLEANING & SANITIZINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business.In order to receive the bes

Strany 3

1. The bin control is a device that senses light,therefore it must be kept clean so it can “see”. Atleast twice a year, remove the bin control sensors

Strany 4

NME454, 654 & FME504, 804January 2007Page 11Clean the air cooled condenser.The air flow on this model is from front to back, sothe inside of the m

Strany 5

The bearing in the breaker should also be checkedat least two times per year.A. Check the bearing by:·removing the ice chute cover·unscrewing the ice

Strany 6

AUGER MAINTENANCEIn some areas, the water supply to the ice makerwill contain a high concentration of minerals, andthat will result in an evaporator a

Strany 7

BIN CONTROLS (Ice Level Sensors)1. Disconnect electrical power.2. Remove front panel.3. Remove control box cover.4. Locate ice chute, at the base of t

Strany 8

SCOTSMAN ICE SYSTEMS775 Corporate Woods Parkway, Vernon Hills, IL 60061800-533-6006www.scotsman-ice.com17-3154-01

Strany 9

INTRODUCTIONTo the owner or user: This manual is intended toprovide you with the information needed to install,start up, clean, and maintain this ice

Strany 10 - NME454, 654 & FME504, 804

FOR THE INSTALLERThese machines fit the following Scotsmanproducts, check sales literature for other possiblecombinations:·SB480 and extensions (with

Strany 11

NME454, 654 & FME504, 804January 2007Page 3*Bin Top Kit RequiredSAMPLE BIN AND MACHINE COMBINATIONSFME804 ON BH550*NME654 ON BH801*FME804 ON BH900

Strany 12

FOR THE INSTALLERLocation:Install the machine be installed in a location whereit has enough space around it to be accessible forservice. A minimum of

Strany 13

NME454, 654 & FME504, 804January 2007Page 5FOR THE INSTALLER: LocationTWO UNITS ON ONE BINALLOW ROOMFOR AIRCIRCULATIONAND SERVICEACCESSALLOW AIR S

Strany 14

FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletAir Cooled Models: Use38" O.D. copper tubing toconnect cold potable water to the38"

Strany 15

FOR THE ELECTRICIANCONFORM TO ALL APPLICABLECODESConnect the electrical power to the machine to thewires in the junction box at the rear of the machin

Strany 16 - 17-3154-01

NME454, 654 & FME504, 804January 2007Page 8INITIAL START UPPre-Start Inspection1. Remove the front and side service panels.2. Check that any shipp

Komentáře k této Příručce

Žádné komentáře