Scotsman C1848R Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Stroj na výrobu ledu Scotsman C1848R. Scotsman C1848R User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Models C1448R, C1848R, C2148R

Installation andUser's ManualModels C1448R, C1848R, C2148R

Strany 2 - Introduction

For The Installer: Remote CondenserLocate the condenser as near as possible to theinterior location of the ice machine.Note: The location of the conde

Strany 3

Precharged Line RoutingDo not connect the precharged tubing until allrouting and forming of the tubing is complete. Seethe Coupling Instructions for f

Strany 4

Coupling InstructionsThe couplings on the ends of the pre-charged linesets are self-sealing when installed properly.Follow these instructions carefull

Strany 5 - RTE10 RTE25 RTE40 RTE75

Plumbing RequirementsAll models require connection to cold, potablewater. A hand actuated valve within site of themachine is required. There is a sing

Strany 6

DrainsAll models require drain tubing to be attached tothem. There is a single ¾” FPT drain fitting in theback of the cabinet.Install new tubing when

Strany 7

ElectricalThe machine is not supplied with a power cord, onemust either be field installed or the machinehard-wired.The dataplate on the back of the c

Strany 8 - Panel Removal

Final Check List:1. Is the unit located indoors in a controlledenvironment?2. Is the unit located where it can receiveadequate cooling air?3. Has the

Strany 9 - 40.35"

Initial Start Up1. Remove front and left side panels. Checkmachine for any packing or wires rubbingmoving parts. Note location of control board inuppe

Strany 10 - C1448, C1848, C2148

AdjustmentsBridge Thickness - For A Service Tech Only1. Push and hold Off till the machine stops.2. Remove evaporator cover.3. Remove curtain.4. Use a

Strany 11 - Precharged Line Routing

Use and OperationOnce started, the ice machine will automaticallymake ice until the bin or dispenser is full of ice.When ice level drops, the ice mach

Strany 12

IntroductionThe design of this modular remote cuber is theresult of years of experience with remote icemachine refrigeration systems. Standard feature

Strany 13 - Plumbing Requirements

SwitchesThere's front access to two switches – on and off.To switch the machine OFF, push and release theOff button. The machine will shut off at

Strany 14

Options and Other InformationSmartBoardWhen this option is present there is an additionaldisplay panel in the area below the main controlboard. It is

Strany 15 - Electrical

Cleaning, Sanitation and MaintenanceThis ice system requires three types ofmaintenance:•Remove the build up of mineral scale from the ice machine’s wa

Strany 16 - Final Check List:

13. Remove water distributors from ice machine.Inspect distributors for restricted orifice holes,including those in the inner tube. Be sure allholes a

Strany 17

Remote condenserThe condenser fins will need to be cleaned.Push and release the Off button. Wait until themachine stops.Note: Lock out the controller

Strany 18 - Adjustments

What to do before calling for serviceReasons the machine might shut itself off:•Lack of water.•Freeze cycle takes too long.•Harvest cycle takes too lo

Strany 19

SCOTSMAN ICE SYSTEMS775 Corporate Woods Parkway, Vernon Hills, IL 60061800-533-6006www-scotsman-ice.com17-3083-04

Strany 20 - OffDe-Scale

Installation: Product SpecificationsLocation LimitationsThis ice system is made up of three parts, the icemaking machine, or head; the remote condense

Strany 21 - 02-4293-01 Rev A

Model Number DescriptionExample•C1448SR-32A•C=cuber•14=nominal capacity in 100s of pounds•48=nominal width of cabinet in inches•S=cube size, S=small o

Strany 22

Product Description and Electrical Requirements*Or HACR circuit breakers.Table notes: Medium cube models have the sameelectrical characteristics as Sm

Strany 23 - Inspect Orifice Holes

Condenser and Ice Machine LayoutsNovember 2006Page 5C1448, C1848, C2148Remote Condenser Models - User Manual.88 DIA. ELECTRICALINLET.65 in1.7 cm27.56

Strany 24 - Remote condenser

WaterThe quality of the water supplied to the ice machinewill have an impact on the time between cleaningsand ultimately on the life of the product. T

Strany 25 - Under Curtain

Panel Removal1. Locate and loosen the two screws at the frontedge of the top panel.2. Pull the front panel out at the top until itclears the top panel

Strany 26 - 17-3083-04

Remote Condenser LocationUse the following for planning the placement of thecondenser relative to the ice machineLocation Limits - condenser location

Komentáře k této Příručce

Žádné komentáře